PortuguêsLogo Dentoflex
Productos

Dentoflex sees the Implantodonty market as a learning and technological development source, not only by the breakthrough in new surgical and prosthetic techniques but also by the agility in obtaining satisfactory results to our customers’ patients.

For this reason, the variety of our product line will match the most varied clinical cases daily found in surgeries.

Surface Treatment

The surface treatment with aluminium oxide blasting,
followed by acid passivation, ideally combines
texture and porosity for an excelent biological effect,
providing conditions for osseous integration and
clinical success. The Dentoflex implants offer surface
rugosity up to 300 times greater than machine-made
surface, increasing up to 6 times the osseous-implant
contact surface and consequently better immediate
mechanical fixation.

Surface with hybrid treatment – Porous Surface

Superficie porosaBlasting with aluminium oxide plus acid attack.
This treatment offers better interlock between the implant and the osseous tissue, by increasing the contact area. The two first spirals are not blasted.

Cutting Design

Progressive cutting, with rosette-shape notches. Blasting is not performed
on this part in order to maintain the cutting.
Detail of smooth surface

Detail between smooth and blasted surface



Detail of blasted

 

Platform

The internal hexagon platform implant – HI - is more appropriate for unitary implants and small screw fixed prosthesis from 2 to 5 teeth, or cement
fixed prosthesis over 5 teeth.
The external hexagon platform implant – HE - can be used for unitary and extensive fixed prosthesis – over 5 teeth – cemented or screwed.

 

Dentoflex implants’ use indication


The distances are always measured from axle to axle both between implants and between implant and tooth

TOOTH

CILINDRIC HI

CILINDRIC HE

CONICAL HI

CONICAL HE

MORSE CONE

FLEX

11 • 21

4,00 • 4,25 • 4,50 • 5,00

4,00 • 4,50 • 5,00

4,25 • 5,00

4,30 • 5,00

3,75 • 4,25

4,25 • 5,00

12 • 22

2,95 • 3,25 • 3,50 • 3,75 • 4,00

3,25 • 3,75

3,75

3,50

3,75

13 • 23

4,25 • 4,50 • 5,00

4,00 • 4,50 • 5,00

4,25 • 5,00

4,30 • 5,00

3,75 • 4,25

4,25 • 5,00

14 • 24

3,25 • 3,50 • 3,75 • 4,00

3,25 • 3,75 • 4,00

3,75

3,50

3,75

15 • 25

3,50 • 3,75 • 4,00

3,25 • 3,75 • 4,00

3,75

3,50

3,75

16 • 26

4,25 • 4,50 • 5,00 • 6,00

4,50 • 5,00

4,25 • 5,00 • 6,00

4,30 • 5,00 • 6,00

3,75 • 4,25

4,25 • 5,00

17 • 27

4,25 • 4,50 • 5,00 • 6,00

4,50 • 5,00

4,25 • 5,00 • 6,00

4,30 • 5,00 • 6,00

3,75 • 4,25

4,25 • 5,00

31 • 41

2,95 • 3,25

3,25

32 • 42

2,95 • 3,25

3,25

33 • 43

4,00 • 4,25 • 4,50 • 5,00

4,00 • 4,50 • 5,00

4,25 • 5,00

4,30 • 5,00

3,75 • 4,25

4,25 • 5,00

34 • 44

3,75 • 4,00 • 4,25

3,25 • 3,75 • 4,00

3,75 • 4,25

4,30

3,50 • 3,75

3,75 • 4,25

35 • 45

3,75 • 4,00 • 4,25

3,25 • 3,75 • 4,00

3,75 • 4,25

4,30

3,50 • 3,75

3,75 • 4,25

36 • 46

4,25 • 4,50 • 5,00 • 6,00

4,50 • 5,00

4,25 • 5,00 • 6,00

4,30 • 5,00 • 6,00

3,75 • 4,25

4,25 • 5,00

37 • 47

4,25 • 4,50 • 5,00 • 6,00

4,50 • 5,00

4,25 • 5,00 • 6,00

4,30 • 5,00 • 6,00

3,75 • 4,25

4,25 • 5,00

 

Utilization

The implants and covering screws undergo a decontamination process, then sterilized by 60 cobaltgamma rays and presented in hermetically closed triple packing. In order to keep its original condition, the packing must only be opened in a sterile environment
(surgical area) and the implant must only be handled with titanium or titanium nitride coated instruments.

 

 

 


Box opening

Safety seal breaking

Removal of the internal tube

Removal of the implant from the internal tube

Pre-insertion with plastic cover

Removal of the plastic cover and insertion with counter-angle and assembler holder

Unscrewing the assembler screw

Removal of the assembler

Placing the covering screw

Dentoflex © 2008 | Desenvolvido por Studio Knove.com
Español EnglishPortuguês